CaTV | Subscriber outlet to subscriber terminal

Image
  Abbreviation Dimension Tolerance L [Length] 68.8 mm(2.71 in.) 1.02 mm (0.040 in.) H [Height] 35.1 mm (1.38 in.) 0.90 mm (0.035 in.) T [Depth] 1.40 mm (0.055 in.) 0.64 mm (0.0.25 in.) R [Corner Radius] 4.06 mm (0.160 in.) max -- C [Distance to first obstruction] 30.5 mm (1.2 in.) min --   Design Consideration for specification from subscriber outlet to subscriber terminal. At least one TV box shall be planned for each room with the following construction and dimension. Wall plates shall have a 75 ohms barrel splice "F" female both ends 3/8" - 32 threads per inch mounted in the center. A washer and nut, matched specifically in the female splice adapter, shall secure the barrel splice to the wall plate. When attaching the cable to the splice adapter, special care shall be taken to avoid over tightening.  EXCERPTS | Cable Television System B...